DEEN
Sprache

LIMAX33 CP Shaft Information System Lift Positioning with Safety Functions for hoisting heights up to 260 m

  • Safe, absolute position detection up to 260 m and safety-relevant switching and control functions in one housing
  • High cost savings due to the reduction of components
  • Up to 3 pairs of safety relays and up to 13 safe inputs for SIL3 compliant controller transfer
  • Floor sensor possible (optional)
  • CANopen interface (DS406) for car position and parameter transfer, DS417and other safe interfaces possible
  • Scaleable functional safety architecture (e.g. solution for EN 81-A3 functionality with 2 safety relais)
  • Travel speed up to 10 m/s
  • Advantages of the magnetic tape technology: insensitive to dirt and smoke, flexible installation
  • EU-Type examination tested, SIL3 (TÜV-certified)
  • Floor sensor possible
  • Quick and easy installation
Product inquiry

MEChANICAL DATA

Measuring principleabsolute, redundant
Repeat accuracy± 1 increment
System accuracy in  µm at 20 °C± (1000 + 100 x L), L= measuring length in meters
Distance sensor/ tapecorrect distance is guaranteed by the magentic tape guidance
Housing materialaluminium
Housing dimensions
(W x B x H)
354 x 136 x 54 mm
Required magnetic tapeAB20-80-10-1-R-D-15-BK80
Basic pole pitch (magnetic tape)8 mm
Max. measuring length260 m
Connections2 outlets with open wire ends for PIO and SCA cables (plug connectors on request); M12 4 pole male for eSGC; according to ICE 61067-2-101
Sensor cable PIO, SCAstandard length 3 m, others on request
Weightapprox. 1400 g without cable, cable: approx. 60 g per meter

 ELECTRICAL DATA

Power supply voltage18 ... 30 VDC (stabilized)
Note: a SELV/PELV power supply must be used!
Residual ripple< 100 mV
DZO output+24 VDC - 20%, max. 200 mA (push-pull)
Current consumptionmax. 600 mA at 24 VDC
InterfacesCANopen (DS406) or DS417, others on request
Resolutionconfigurable up to 62.5 µm, default setting: 1 mm
Max. operating speed10 m/s
Digital input voltage18 ... 30 VDC for HIGH level; open for LOW level
Relay contact rating OC, SR1, SR2

0 ... 230 VAC (max. 250 VAC), max. 2 A;
or 24 VDC (max. 30 VDC), max. 1 A;
or 110 VDC, max. 250 mA;
each with a resistive/inductive load with L/R < 40 ms

Rating for external supply of SGC-actuator24 VDC, min. 18 V; max. 30 V; constraints for connected trip coil must be observed

miscellaneous

Max. operating time20 years
Safety relay contact reaction time< 55 ms
Solid state contact (eSGC) reaction time< 45 ms

CONFORMANCE / STANDARDS / CERTIFICATION

Achived SILSIL3 (TÜV-certified)
Fulfilled standardsEN 81-20
Type-examinationEU according to EN 81-20

ENVIRONMENTAL CONDITIONS

Storage temperature-25 ... +85 °C 
Operating temperature-20 ... +65 °C, -25 ... +85 °C on request
Humiditiy95 %, not-condensing
Operating heightmax. 2000 m above sea level
Protection classIP54 (acording to EN 60529), higher on request
Interference emission/ immunityEN 12015 / EN 12016
Vibration/ shock resistanceEN 60068-2-6, EN 60068-2-27
EN 60068-2-29

FLYER

Flyer LIMAX33 CP

SAFETY MANUAL

LIMAX33 CP

MOUNTING INSTRUCTION

LIMAX33 CP