Floor Sensors for Elevator Applications exact Detection of Door Zones in tall Buildings
- Exact detection of door zones
- Automatic teach-in process possible
- Easy and space-saving insterllation
- Resistant to dirt, moisture and smoke
- IP67 high protection class
MECHANICAL DATA
Repeat accuracy | ± 1 mm |
Distance between sensor and magnetic tape | 3 ... 25 mm |
Lateral guiding tolerance | ± 0.5 mm |
Sensor housing material | zinc die casting |
Sensor housing dimensions (L x W x H) | sensor: 50 x 24 x 26 mm magnet: 30 x 30 x 6 mm |
Connection | open cable ends |
Weight | approx. 40 g without cable, cable approx. 60 g per meter |
ELECTRICAL DATA
Power supply | 24 VDC ± 20% |
Periodic and random deviation | 24V: <10% |
Current consumption | max. 40 mA |
Output signals | LOW-aktiv, push/ pull - short circuit proof |
Sensor cable | 5 m standard cable length, others on request, drag chain compliant |
ENVIRONMENTAL CONDITIONS
Storage temperature | -25 ... +85 °C |
Operation temperature | -10 ... +70 °, -25 ... +85 °C on request |
Protection class (sensor) | IP67 |
MAGNET
dimensions (L X B X H) | 30 x 30 x 6 mm |
storage temperature | -5 ... +65 °C |
operation temperature | -25 ... +85 °C |
protection class | IP67 |