| Measuring principle: | absolute |
| Measurement: | linear |
| Maximum measuring length | 786 m |
| Speed: | max. 16 m/s |
| Resolution: | 0,0625 mm |
| Repeat accuracy: | +/- 1 Increment |
| System accuracy at 20°C: | +/- (1000 µm + 100 µm x L[m]) L = measuring length in meter |
| Distance from sensor to magnetic tape | 4.5 mm (semi-guided variant) max. 8 mm (unguided variant) |
| Dimensions (without cable): | semi-guided variant: L x W x H = 524 x 81 x 55 mm unguided variant: L x W x H = 482 x 78 x 36 mm |
| Housing material: | aluminium |
| Connection: | circular plug 5-pole M12 |
| Weight without cable: | approx. 1030 g (semi-guided) / 820 g (unguided) |
| Required magnetic tape: | semi-guided variant: AB20-120-10-1-R-D-16-BK80 unguided variant: AB20-120-20-1-R1-C-16A-4943F (0 m … 285 m) AB20-120-20-1-R1-C-16B-4943F (285 m … 570 m) AB20-120-20-1-R1-C-16C-4943F (570 m … 786 m) |
| Supply voltage: | + 18 … 29 VDC (stabilized) in dual-channel operation + 10 … 18 VDC (stabilized) in single-channel operation You must use a power supply with Safety Extra Low Voltage (SELV) or Protective Extra Low Voltage (PELV). |
| Residual ripple: | < 100 mVpp |
| Reverse voltage protection: | integrated |
| Power input: | max. 200 mA @ 24 VDC without loading the output for the door zone indication |
| Interfaces: | RS-485 |
| Protection of the outputs/ interfaces: | RS-485 output: short-circuit-proof output door zone indication: short-circuit-proof to GND, but not to +24V |
| Cable length: | according to EIA RS-485 specifications |
| Maximum operating time: | 20 years |
| Storage temperature: | -20 °C … +85 °C |
| Operation temperature: | -10 °C … +70 °C |
| Humidity: | max. 95 %, non-condensing |
| Protection class: | IP54 (according to EN 60529) |
| Operation height: | max. 2000 absolute altitude |
| EMC transient emission/immunity: | according to EN 12015 / EN 12016 |
| Vibration/shock resistance: | according to EN 60068-2-6 / EN 60068-2-27 |